期刊导航

论文摘要

纤维桩和粘接系统对粘接界面形态及破坏方式影响的研究

Morphological and failure mode study of different fiber posts luted with different adhesive systems to root dentin

作者:张晓 李津乐 郝亮

Author:ZHANG Xiao1, LI Jin-le2, HAO Liang2

收稿日期:2011-04-25          年卷(期)页码:2011,29(02):132-132-135

期刊名称:华西口腔医学杂志

Journal Name:West China Journal of Stomatology

关键字:纤维桩,自粘接树脂黏固剂,界面形态学,

Key words:fiber post,self-adhesive resin cement,interface morphology,

基金项目:

中文摘要

目的比较不同粘接系统粘接2种纤维桩后在桩道不同深度的粘接界面形态和界面破坏方式。方法选取36颗新鲜上颌前磨牙,将其分成A、B、C、D组,A组:自粘接树脂黏固剂和POPO玻璃纤维桩;B组:全酸蚀粘接系统和POPO玻璃纤维桩;C组:自粘接树脂黏固剂和Para Post玻璃纤维桩;D组:全酸蚀粘接系统和Para Post玻璃纤维桩。根管充填、桩道预备后粘接纤维桩于根管中。制备厚约1 mm薄片推出实验试样,万能力学测试机进行加载,体视显微镜观察粘接界面气泡率、裂缝率和破坏方式。结果对于粘接界面树脂层气泡率,B组(64.2%)、D组(66.7%)显著高于A组(5.8%)、C组(13.7%)(P<0.001)。D组粘接界面裂缝率(41.2%)显著高于A组(13.5%)和C组(11.8%)(P<0.008 3)。除A组与B组间外(P=0.69),其余各组试件破坏方式间差异有统计学意义(P<0.008 3)。结论粘接界面树脂层气泡率与使用的树脂粘接系统有关;纤维桩-树脂-牙本质粘接界面形态特征与破坏方式间存在差异,2个界面的性能共同决定纤维桩桩道内的粘接固位能力;纤维桩和粘接系统间存在显著的相互作用。

英文摘要

Objective To investigate the correlation of morphological characteristics and failure modes of two types

of glass-fiber posts luted with self-adhesive resin cement and etch-and-rinse adhesive system. Methods Thirty-six

intact single-rooted premolars were collected and removed the crown. After root canal therapy, teeth were randomly divided into 4 groups. Group A: Self-adhesive with POPO fiber post. Group B: Etch-and-rinse with POPO fiber posts. Group C: Self-adhesive with Para Post. Group D: Etch-and-rinse with Para Post. Each root was sectioned into six 1mmthick serial slices and a push-out test was performed. The dentin-cement-post adhesive interface of each specimen and failure modes after fracture were evaluated by stereomicroscope observation. Results Interface morphology observe indicated that voids present in group B(64.2%) and D(66.7%) were significantly higher than group A(5.8%) and C (13.7%)(P <0.001). Interface gaps appeared at the resin -dentine interface in group D(41.2%) were significantly higher than group A(13.5%) and C(11.8%)(P<0.008 3), and the failure modes in each group were significantly different (P<0.008 3) except for group A and B(P=0.69). Conclusion Voids present in cement layer were associated with the luting agent involved. Morphological characteristics of the fiber post-resin luting agent-root dentin adhesive interface were discrepant with failure modes in different root region. There were interaction between adhesive systems and fiber posts.

下一条:正常人发音时软腭形态在数字化头影测量图像中的表现

关闭

Copyright © 2020四川大学期刊社 版权所有.

地址:成都市一环路南一段24号

邮编:610065