In order to investigate the working behaviors of bonded rebar under fire (high temperature), 25 specimens were designed for the test of pullout strength including those working in the ambient circumstance.Two embedment depths (10 d, 15 d) were considered. Records were made on the temperatures inside the specimens,bonded rebar displacements and the pullout strengths. The pullout strengths of 10 d and 15 d specimens at different temperatures were analyzed and contrasted the pullout strength of 15 d specimens with that of 10 d specimens at the same temperature.The tests showed that the pullout strength decreases when the specimen is under high temperature. Especially, when the temperature is above 350 ℃, the pullout strength is about 10%~20% that of the ambient circumstance.