期刊导航

论文摘要

隙料厚度和覆盖面积对CerconCAD/CAM底层冠适合性的影响

Influence of different spacer thickness and spacer coverage area on the adaptation of Cercon CAD/CAM

作者:李明哲 三浦宏之 进千春 山崎有子 宫坂宗永

Author:LI Ming-zhe1, Miura Hiroyuki2, Shin Chiharu2, Yamazaki Ariko2, Miyasaka Munenaga2

收稿日期:2009-04-25          年卷(期)页码:2009,27(02):195-

期刊名称:华西口腔医学杂志

Journal Name:West China Journal of Stomatology

关键字:计算机辅助设计与制造,适合性,氧化锆,

Key words:computer aided design/computer aided manufacture,adaptation,zirconium dioxide,

基金项目:

中文摘要

目的通过研究隙料厚度和覆盖面积对Cercon CAD/CAM底层冠边缘和内部适合性的影响,评价CerconCAD/CAM系统的加工精度。方法通过模拟下颌第一磨牙,加工1个不锈钢主模型。扫描后,根据不同隙料厚度和覆盖面积,分为6组,分别为S10C70、S10C90、S30C70、S30C90、S60C70、S60C90,每组6个试件。采用硅橡胶印模复制技术和图像分析系统测量底层冠内部适合性和边缘适合性。结果方差分析显示底层冠内部适合性的差异与测量位置、隙料厚度和覆盖面积有关。覆盖面积不同组间差异有统计学意义。隙料厚度10 μm和30 μm组间、10 μm和60 μm组间差异有统计学意义。内部适合性不均匀,远中与近中相对位置间、颊侧与舌侧相对位置间有显著差异。隙料厚度30 μm和60 μm组间差异无统计学意义。平均边缘适合性为(27.7±7.6)μm,近远中和颊舌侧间边缘适合性差异有统计学意义;近中与远中边缘适合性、颊侧与舌侧边缘适合性间差异无统计学意义。结论CerconCAD/CAM新系统制作的氧化锆底层冠有良好的边缘和内部适合性,达到临床可接受范围。隙料厚度和覆盖面积对底层冠内部适合性有显著影响。

英文摘要

Objective To evaluate the accuracy of Cercon CAD/CAM system and the influence of different spacer thickness and spacer coverage area on the internal and marginal fit of the copings. Methods A stainless steel master model of first molar was replicated. After scanning, designs of copings were made with different spacer thickness and spacer coverage area. There were six groups: S10C70, S10C90, S30C70, S30C90, S60C70, S60C90. Measurements of the adaptation were performed with silicone impression material and an image analysis system. Results Univariate ANOVA showed that variation in the internal fit of copings was related to measuring location, spacer thickness and spacer coverage area. There was significant difference between different spacer coverage area groups, and significant difference between spacer thickness 10 μm and 30 μm groups, 10 μm and 60 μm groups, no significant difference between spacer thickness 30 μm and 60 μm groups. Mean marginal fit was (27.7 ±7.6)μm. There was statistically significant difference between both mesial, distal marginal gaps and both buccal, lingual marginal gaps. No difference between mesial and distal marginal gaps, and between buccal and lingual marginal gaps. Conclusion The accuracy by Cercon CAD/CAM system for the marginal and internal fit of zirconium dioxide copings is well within the range of clinical acceptability. Spacer thickness and spacer coverage area have statistically significant influence on the internal fit.

关闭

Copyright © 2020四川大学期刊社 版权所有.

地址:成都市一环路南一段24号

邮编:610065